Auto reset
Auto-Reset GFCI Plug
Pool pumps, hot tubs and equipment left running
- Restores power by itself once it's safe
- Self-tests on power-up and keeps checking
- 3-prong, 15A / 125V, rainproof
If your GFCI plug trips, won't reset, or died in the rain, your pressure washer, pool pump or power tool usually isn't broken. The plug is. Swap it in about 5 minutes.
Two replacement plugs that wire onto your existing cord, and one plug-in GFCI cord that needs no wiring at all.
Auto reset
Pool pumps, hot tubs and equipment left running
Manual reset
Pressure washers and hand-held tools
No wiring
Outdoor tools, holiday lights, garage and patio
All three give the same Class A shock protection. The difference is what happens after a trip, and whether you want to wire anything.
…run a pool pump, hot tub, or anything left running on its own
After a power blip or a cleared fault, it restores power by itself, so your pump doesn't sit dead until someone notices. A real ground fault still keeps it tripped.
Auto-Reset GFCI Plug…hold the tool in your hands: pressure washer, saw, grinder
After a trip, power stays off until you press RESET. You decide when the tool comes back on, never by surprise.
Manual-Reset GFCI Plug…don't want to cut or rewire anything
Plug it into the wall, plug your tools or lights into it. Three lighted outlets, GFCI protection for all of them, zero wiring.
3 ft GFCI Extension Cord| Spec | Auto-Reset GFCI Plug | Manual-Reset GFCI Plug | 3 ft GFCI Extension Cord |
|---|---|---|---|
| Type | Replacement plug, wires onto your cord | Replacement plug, wires onto your cord | Plug-in cord, no wiring |
| After a trip | Restores power automatically once safe | Stays off until you press RESET | Restores power automatically once safe |
| Protection | Class A, trips at 4–6 mA in 25 ms | Class A, trips at 4–6 mA in 25 ms | Class A, trips at 4–6 mA in 25 ms |
| Rating | 15A · 125V · 1800W | 15A · 125V · 1800W | 15A · 125V · 1800W |
| Cord | Fits 18/16/14 AWG 3-wire cords | Fits 18/16/14 AWG 3-wire cords | 3 ft, 12/3 SJTW outdoor jacket |
| Outlets | — | — | 3 lighted outlets |
| Install | About 5 minutes, one screwdriver | About 5 minutes, one screwdriver | None, plug and use |
| Certification | ETL Recognized · UL 943 | ETL Recognized · UL 943 | ETL · UL 943 |
| Best for | Pool pumps, hot tubs, unattended equipment | Pressure washers and hand-held tools | Outdoor tools, holiday lights, garage use |
Each plug ships with the strain relief, back cover, grommets for 18, 16 and 14 AWG cords, and screws already in place.
The GFCI extension cord needs no install. Plug it into the wall and you're protected.
Unplug the cord from the wall. Cut off the dead plug. Strip the outer jacket back 21–22 mm, then each wire 8–9 mm.
BLK → brass WHT → silver GRN → green. Tighten each screw clockwise.
Tighten the strain-relief clamp over the outer jacket and close the housing so the gasket seals.
Plug in → light on. Press TEST → power cuts. Press RESET → power back. You're protected.
The replacement plugs self-test within 5 seconds of power-up, then again every 15 minutes, so you know the protection is actually working.
Factory-tested to more than 6,000 cycles, double what the UL 943 standard asks for.
Gasket-sealed, rainproof housings made for outdoor work. Keep the plug itself out of standing water.
Color-coded terminals and clear LINE/LOAD markings. If you can strip a wire, you can fit it.
Order direct from Kaper. Secure checkout, tracked US delivery, 30-day returns.
Always follow the included instructions and local electrical codes. Unplug equipment before installing. If you're not comfortable working with electrical wiring, consult a licensed electrician. A GFCI reduces the risk of electric shock but does not replace safe work practices.